Characteristics
Application
| Color | Hardening Agent | Thermal Conductivity (W/m∙K) | TVOC (mg/m2∙h) | Density (g/mL) | Volume Solid |
|---|---|---|---|---|---|
| White (matt) | No need | 0.036 | 0.35 | 0.40 | 70% |
Condensation and Mold Prevention
Buildings with condensation and fungal problems (valcony/housing/warehouse, etc.)
Insulation Construction
Inside a building that requires improvement of internal insulation (dressroom, multi-purpose room, etc.)
Repair of damaged insulation board
Damaged parts of insulation bard that occur during construction, where the fault has occurred
(Condition of 30℃, humidity 75%, input refrigerant temperature 9℃ (Blank surface temperature 18.2℃) in the Chamber)
| Blank | A | B | C | AEROFIX | |
|---|---|---|---|---|---|
| Condensation Test Preparation | ![]() |
![]() |
![]() |
![]() |
![]() |
| Condensation Test Result | ![]() |
![]() |
![]() |
![]() |
![]() |
| Blank | AEROFIX | A | B | C | ||
|---|---|---|---|---|---|---|
| Condensation Performance | Condensation generation | - | Non | Severe Level | Severe Level | Severe Level |
| Condensation/Film strength change | - | No deformation | Deformation | Deformation | Deformation on repeated exposure | |
| Result | - | ★★★★★ | ★★★ | ★★ | ★ | |
| Insulation Performance | Surface Temp / Dew point Temp | 18.2 / 25.1 | 27.2 / 25.1 | 22.0 / 25.1 | 20.1 / 25.1 | 21.3 / 25.1 |
| Temperature difference | -6.9 | 2.1 | -3.1 | -5.0 | -3.8 | |
| Result | - | ★★★★★ | ★★ | ★ | ★★ | |
The temperature at which the condensation begins to form on the surface, the higher the surface temperature than the condensation point temperature, the less condensation occurs.
Superior Anti-Condensation Performance
AEROFIX does not produce condensation, and there is no deformation or lifting due to reduced water resistance even when left unattended for a long time.
(Test conditions: 30°C, 70% humidity, 15°C Blank, 23.9°C dew point in Chamber.)
Condensation generation
Long-term neglect of Condensation stateStrong Heat-Resistance Effect
Heat shield effect of about 31℃ in AEROFIX construction compared to normal CRC board on a heat plate heated to 100℃

Prevention/Repair Condensation and Mold
AEROFIX solves mold problems and condensation inside buildings such as apartments, houses, warehouses, and basement through Aerogel’s excellent insulation performance.


Insulation Construction/Repair
AEROFIX improves insulation inside the buildings with the low thermal conductivity of Aerogel.


Recommended construction thickness: 2T
(with indoor temperature of 22°C, wall temperature of 10°C, humidity of 50%)
Depending on the site conditions, the thicker the construction thickness, the better the performance can be achieved.
| Product Mix / Masking Process |
|---|
|
| Plastering Work |
|---|
|
| Spray Operation |
|---|
|